This guide contains all the information you need to know to get your new gear up and running, along with handy links to any available accessories and other relevant information. If you require technical support, please contact our support team for assistance. Contact details are contained within this guide.

Failure to follow these instructions may result in personal or property injury, may reduce the lifespan of your product, and may void your warranty.
  • RISK OF FIRE, EXPLOSION AND BURNS: 
    Working in the vicinity of lead acid batteries is dangerous. Explosive gases can develop during 
    normal battery operation. Be certain there is enough ventilation to release the gases. Do not smoke 
    when in the vicinity of the battery under charge.
  • Ensure the red is connected to the positive terminal and the black is connected to the negative terminal 
    if using clamps to connect to your battery. Connecting to the wrong terminals may damage the unit.
  • Check the manufacturer’s data for your battery and ensure the maximum voltage of the profile you 
    select does not exceed the recommended maximum charge voltage.
  • Confirm that the plugs are tightly connected to avoid excessive heating from a loose connection.
  • Be careful not to short-circuit the battery connections.
  • Accidental shorting of the terminals or wiring can result in sparks, causing personal injury or a fire 
    hazard. We recommend that you cover up the panel with a soft cloth during installation of the 
    regulator to block all incoming light. This will ensure that no damage is caused to the solar panel or 
    battery if the wires are accidentally short-circuited.
  • The battery box should not be used by children or persons with reduced physical, sensory or mental 
    capabilities, or lack of experience and knowledge, unless they are supervised or have been 
    instructed on how to use the appliance by a person responsible for their safety.
  • Do not alter or disassemble the battery box under any circumstances. Incorrect handling or 
    reassembly may result in a risk of electric shock or fire and may void the unit warranty.
  • This product is designed to operate in ambient temperatures between -10°C and 60°C. Do not 
    operate outside of this temperature range. Do not use this product to charge a frozen battery.
  • Discontinue use if battery becomes excessively warm.

PRODUCT OVERVIEW

The Heavy Duty Battery Box MAX converts a compatible large form factor 12V auxiliary battery into a portable power station. It provides 6 high-current IN/OUT Anderson-style connections, two 12V cigarette sockets, USB charging, wireless charging and provisions for mounting and connecting an internal DC-DC charger.

 Connection Qty / Rating Protection Typical Use
USB-C 2 x 45W 1x 15A blade fuse (shared) Charging compatible phones, tablets and USB-C devices.
USB-A 2 x QC 3.0
Quick-charge USB accessories.
12V cigarette sockets 2 x 10A 1x 15A blade fuse (shared) Low draw 12V accessories
50A Anderson-style 6 x 50A Individual 60A midi fuse per plug 12V inputs or outputs using correctly rated plugs and cable.
175A Anderson-style 1 x 175A 200A midi fuse Optional inverter cable kit or jump-start leads.
Wireless charging pad 1 x 15W max. / Qi-compatible phone or accessory charging.
3-pin vehicle input 1 x 50A 60A midi fuse (not pre-wired) Dedicated input for an optional internal DC-DC charger (not included).
Solar input 1 x 50A / Dedicated solar input for an optional internal DC-DC charger (not included).

PACKAGE CONTENTS

 Qty Description
1 Heavy Duty Battery Box MAX
2 Tie down straps + hardware
2 Terminal covers
1 Allen key
4 Lid fastening bolts
1 DC-DC charger mounting plate (fitted)
5 Anderson-style terminals (for DC-DC connection)
4 DC-DC charger fastening bolts + nuts

INSTALLATION

Before beginning the installation of your battery inside the battery box, ensure it can fit inside the internal cavity, and ensure you have all the included hardware.

Remove the lid from the battery box and leave it to the side. Lay the ends of the securing straps out of the box and gently lower the battery into place.

To secure the battery inside the box, take the ends of one set of straps, and thread the rounded end through the strap loop on the other end. Bring the rounded end up and over the strap loop, and pull it back on itself until the strap is tight around the battery. Finally, stick the remaining strap length to itself with the velcro and tuck the end beside the battery.

Repeat this process with the other strap, and the battery should hold firm inside the box.

Using a 13mm socket or spanner, remove the terminal bolts from the battery. 

Take the red cable attached to the lid and thread the bolt through the eye terminal (ensure the terminal is flat side down). Fasten the bolt back into the positive terminal, ensuring the polarity is correct. Repeat this step with the black cable on the negative terminal. 

One final check that the connections are secure, and you can flip over the lid and seat it on the bottom housing.

The housing is not symmetrical, so to ensure a correct fitment, rotate the lid until the battery isolation switch is on the same side as the Hardkorr logo on the housing.

Secure the lid with the four included black bolts, using the included hex-key.

USING YOUR BATTERY BOX

 MAIN SWITCH DISPLAY OUTPUTS
Turn ON to connect the battery to the factory-wired outputs. Turn OFF before installation, maintenance, storage or changing high-current leads.

Shows battery voltage and general SOC for WET batteries. For accurate lithium state of charge, use a shunt-based battery monitor.

With the box isolator in the ON position, tap the power button on the display to turn in on/off.

Keep loads within the rating of the socket, cable, installed battery and battery management system.

Charging Options

CHARGING SOURCE CORRECT CONNECTION
Regulated AC-DC charger Connect to one of the 6 IN/OUT 50A Anderson ports.
External solar controller Connect to one of the 6 IN/OUT 50A Anderson ports.
Vehicle alternator Use the dedicated Alternator Input only after an internal DC-DC charger has been installed and wired.
Solar panel via DC-DC Use the dedicated Solar Input only after an internal DC-DC charger has been installed and wired.

WARNING: Do NOT connected an unregulated solar panel to any of the 6 IN/OUT Anderson style plugs. 

Only use the 175A Anderson style plug with a high-current cable kit and a battery/BMS capable of the required continuous and surge current.

SPECIFICATIONS

SPECIFICATION HKBBOXMAX
Construction ABS plastic (meets UL-94V-0 standard)
Battery Compatibility 12V Lithium, AGM, Calcium, Wet, Gel
Cable Gauge 2AWG (33.6mm²) to battery and 175A Anderson port; 10AWG (6mm²) to 50A Anderson ports; 14AWG (2.5mm²) to cig & USB ports
Isolator Switch Rating 200A
Product Dimensions 483 (W) x 295 (H) x 375 (D) mm
Max. Battery Dimensions 383 (W) x 205 (H) x 255 (D) mm
Max. Battery Weight 35.0kg
Operating Temperature -10°C to 60°C

TROUBLESHOOTING

 SYMPTOM POSSIBLE CAUSE ACTION
No display or output Main switch OFF, battery flat/disconnected or loose terminal. Turn OFF. Check battery voltage, polarity and terminal security, then recharge with a suitable charger.
Alternator Input does not charge Anderson input is unwired or no internal DC-DC charger is installed. This is normal in the factory configuration. Install and wire a compatible DC-DC charger.
Solar Input does not charge Anderson input is unwired or no internal DC-DC charger is installed. Use a standard 50A port with an external solar controller, or install and wire a compatible DC-DC charger.
Standard 50A port does not charge Wrong polarity, loose connector or charging source not regulated/configured. Check the charger or solar controller, battery profile, polarity and connector engagement.
USB, wireless or 12V output stops Battery voltage low, load exceeds rating, cable/device incompatible or plug loose. Check battery voltage and device rating. Reconnect using a known-good cable or accessory.
Connector becomes hot Loose, dirty or damaged plug, or excessive current. Stop use immediately. Allow it to cool, then repair or replace the affected connection.
Battery is hot, swollen or smells unusual Battery fault, incorrect charging or excessive load. Switch OFF and isolate chargers and loads when safe. Do not reuse the battery until assessed.

WARNING: If the fault cannot be corrected safely, or if the enclosure, switch, wiring or connectors are damaged, discontinue use and contact Hardkorr support.

OPTIONAL DC-DC CHARGER INSTALLATION

NOT CONNECTED OUT OF THE BOX: The Alternator Input and Solar Input Anderson-style sockets are supplied empty and unwired. They are not connected to the battery, main switch or factory-wired outputs.

 Tools Required Parts Required
Side/flush cutters 2x Ring terminals
Ring terminal crimping tool Heatshrink
Anderson crimping tool Cable ties
Phillips Head screw driver Cable sheathing (optional, depending on charger cable size)
10mm socket
8mm socket
Heat gun / torch

The below steps show how to install a Hardkorr 40A DC-DC charger (HKPDCDC40UB) into the Battery Box Max:

  1. Undo the 4 screws holding the mounting plate in place

  2. Mount your DCDC to the plate using the included bolts + nuts
  3. Undo the 4 screws holding the rear plug housing in place

  4. De-pin the alternator and solar Anderson plugs on the DCDC charger and re-connect the cables to the matching plugs on the box (3-pin plug is alternator input, 2-pin black plug is solar input)
  5. De-pin the output Anderson plug (red + black wire) from the DCDC.
  6. Cut the Anderson terminals off of both wires and terminate a 6mm ring terminal on each.
  7. Bolt the negative cable (black) to the negative stud under the lid.

  8. Bolt the positive cable (red) to the spare midi fuse under the lid. Ensure that the lug doesn't sit on top of the plastic part of the fuse.

  9. Secure the rear plug housing back in place using the 4 screws.
  10. Secure the mounting plate back to the box using the 4 original screws.
  11. Turn on the isolator switch to power the DC-DC charger on
  12. Following your DC-DC charger manual, change the change profile to match your secondary battery chemistry
  13. Connect the alternator and/or solar Anderson plugs to the box alternator/solar input plugs and test the DC-DC charger functionality