12/24V Solar MPPT Owner's Guide

12/24V Solar MPPT Owner's Guide

This guide contains all the information you need to know to get your new gear up and running, along with handy links to any available accessories and other relevant information. If you require technical support, please contact our support team for assistance. Contact details are contained within this guide.

Please ensure you have read through ALL warnings prior to setting up your product

  • Working in the vicinity of lead acid batteries is dangerous. Explosive gases can develop during normal battery operation. Be certain there is enough ventilation to release the gasses. Do not smoke when in the vicinity of the battery under charge.
  • Ensure the red is connected to the positive terminal and the black is connected to the negative terminal if using clamps to connect to your battery. Connecting to the wrong terminals may burn out the regulator.
  • Do not use the regulator to charge non-rechargeable batteries; this may result in harm to the user and/or damage to the equipment.
  • Check the manufacturer’s data for your battery and ensure the maximum voltage of the profile you select does not exceed the recommended maximum charge voltage.
  • Confirm that the screw terminals are tightly connected to avoid excessive heating from a loose connection, check periodically.
  • Be careful not to short-circuit the battery connections.

PRODUCT OVERVIEW

The HKPSOLR40A and HKPSOLR60A use maximum power point tracking to convert available solar energy into controlled charging current for a 12V or 24V battery system. Both models share the same control layout, battery profiles and monitoring functions.

Key Features

  • 40A and 60A output options for 12V or 24V systems

  • 15-94V DC solar input range

  • MPPT efficiency of 99.5%

  • Lithium and lead-acid battery profiles plus Custom settings

  • Hardkorr app monitoring and custom charge-profile setup

  • Temperature sensor and optional remote display support

HKPSOLR40A HKPSOLR60A
  • Maximum output: 40A
  • Dimensions: 195 x 140 x 73
  • Weight: 1.2kg
  • Maximum output: 60A
  • Dimensions: 195 x 203 x 85
  • Weight: 1.9kg

Protection Functions

  • Reverse-polarity protection for the solar and battery connections.
  • Reverse-current protection to prevent battery discharge into the solar array at night.
  • Over-temperature protection with automatic charging-current reduction.
  • Over-voltage protection at the solar input and battery output.

PRODUCT DIMENSIONS AND MOUNTING

Mount the controller vertically (wall) or horizontally (floor) on a firm surface, with the terminals facing down and sufficient space for cable routing and cooling. The location must be indoors or protected from weather.

HKPSOLR40A

HKPSOLR60A

Mounting Checklist

1

Choose a dry, protected and well-ventilated location close to the battery.
2 Use the mounting dimensions above to mark and drill the fixing points.
3

Secure the controller vertically (wall) or horizontally (floor) against the mounting surface.

4 Leave the terminal area and heat sink unobstructed for wiring and cooling.


CONNECTING THE SOLAR CONTROLLER

WARNING: Cover or isolate the solar panels and remove the solar and battery fuses before opening the terminal cover or connecting cables.

Connection Layout

Fuses

 Circuit HKPSOLR40A HKPSOLR60A Location

Solar positive

50A inline fuse 80A inline fuse As close to the solar source as practical
Battery positive 50A inline fuse 80A inline fuse As close to the battery as practical

Cable Size

Minimum Cable Size (MPPT to Battery)
Total Length HKPSOLR40A HKPSOLR60A
Less than 3m 10AWG 8AWG
3-6m 8AWG 6AWG
6-9m 6AWG 4AWG

Cable Strand Size

Use flexible, fine-stranded copper cable for all battery and PV connections.

  • Strand size: Each individual copper strand must be no larger than 0.4mm in diameter, equivalent to approximately 0.125 mm² in cross-sectional area. This limit applies to each strand, not the complete cable.
  • Temperature rating: Use cable rated for continuous operation at 90°C or higher.
  • Cable construction: Use Class 5 or Class 6 flexible copper cable to IEC 60228, and check that its individual strands meet the size limit above.
  • Cable selection: Select the total conductor size to suit the current, cable length and equipment terminals. Tri-rated cable may be suitable, provided it meets these requirements.

WARNING: Thick strands may not make adequate contact inside the equipment terminals. Poor contact increases electrical resistance and can cause severe overheating or fire.

Location Checklist

1

Mount as close to the battery as practical to minimise cable loss.
2 Use a vertical, dry, ventilated location where the display remains visible.
3

Allow clear access to the fuses, terminals and optional sensor connections.

4 Keep the controller away from battery gases, fuel, heat sources and water spray.

Installation Procedure

1

Confirm the controller is securely mounted and that the solar array and battery are isolated.
2 Prepare correctly sized stranded copper cables and crimp suitable terminals to the solar and battery leads.
3 Open the front access panel and remove the rubber terminal mask. Loosen the terminal screws.
4 Connect the solar and battery cables to the terminals exactly as labelled. Check positive and negative polarity before tightening.
5 Connect the chassis ground. Connect the optional battery temperature sensor and remote display if fitted.
6 Secure every cable firmly. Refit the rubber terminal mask.
7 Install the solar and battery fuses, then uncover or reconnect the solar array.
8 The controller starts automatically. Confirm the display completes its self-test and shows the correct system voltage.
9 Change the charge profile via the screen or Bluetooth app to suit your battery chemistry (see below for details)

Note: The solar controller uses a common negative connection. Follow the system wiring diagram and all local installation requirements.

OPERATING THE DISPLAY

The front panel is used to view live solar and battery information, select the system voltage and choose the battery charging profile.

Start-Up Display

At power-up, the controller checks the LCD segments, displays the software version and then shows the detected battery system voltage and controller current rating.

View Operating Data

Button Press repeatedly to view
PV / - Solar input voltage, solar current, solar power and accumulated solar energy (kWh).
BATT / + Battery voltage, charging current, charged capacity (Ah) and battery temperature when the external sensor is fitted.
SET Switch the temperature display between °C and °F. Hold for 3 seconds to enter setup.

The battery bar graph indicates approximately 25%, 50%, 75% and 100% state of charge. The display alternates between the battery voltage and FUL when the battery is fully charged.

Note: The battery bar graph indicator will not indicate an accurate state of charge for LiFePO4 batteries.

CONTROLLER SETTINGS (BASIC SETUP)

Select the System Voltage

1

Hold SET for 3 seconds to open the system-voltage setting.
2 Press PV / - or BATT / + to select 12V, 24V or AUTO.
3 Press SET to confirm. In AUTO mode, the controller detects whether a 12V or 24V battery is connected.

Display sequence:

Select the Battery Type

1

After the system voltage is confirmed, the battery-type setting flashes on the display.
2 Use PV / - or BATT / + to move through the available battery profiles.
3 Press SET to confirm the selected profile. AGM is the default setting.

Display sequence:

Note: the controller will memorize all selected settings.

Battery type Absorption voltage (12V) Absorption voltage (24V) Note
LCO 12.6V 25.2V Only recommended for a 3-series lithium cobalt oxide battery.
LTO 14.0V 28.0V Lithium titanate
LFP 14.2V 28.4V Lithium iron phosphate / LiFePO₄
Gel 14.1V 28.2V No equalization
AGM 14.4V 28.8V No equalization
WET 14.7V 29.4V Flooded lead-acid: equalization available
Crystal 14.7V 29.4V Lead-crystal; no equalization
Calcium 14.9V 29.8V Equalization available
Custom 13.2-15.5V 26.4-31V Use only when the battery manufacturer provides the required setpoints.
WARNING: Selecting the wrong battery profile can damage the battery. Confirm the chemistry and charging voltage with the battery manufacturer before charging.

CONTROLLER SETTINGS (CUSTOM)

Use the Custom profile only when the battery manufacturer has supplied all required charging voltages and times. The values below are the available 12V-system adjustment ranges.

Available Parameters

Display Settings Range (12V) Range (24V) Step
AbS.U Absorption voltage 13.20-15.50V 26.40-31.00V 0.05V
AbS.T Absorption duration 5-500 min 5 min
EqL.U Equalisation voltage 13.20-16.20V 26.40-32.40V 0.05V
EqL.T Equalisation duration 5-500 min 5 min
EqL.P Equalisation interval 0-100 days 1 day
FLT.U Float voltage 13.00-14.00V 26.00-28.00V 0.05V
rST.U Restart voltage 12.50-13.50V 0.05V

Note: Setting EqL.P to 0 days disables scheduled equalisation. 

WARNING: Never enable equalisation for Gel, AGM, Crystal or lithium batteries. Equalisation is only intended for compatible WET and Calcium batteries.

Changing Custom Settings

1

Select Custom as the battery type.
2 The display alternates between the parameter code and its current value.
3 Press PV / - to decrease the value or BATT / + to increase it.
4 Press SET to save the value and move to the next parameter.
5 After the restart voltage is confirmed, all custom settings are stored.

Display sequence:

After the final custom parameter is confirmed, the controller saves the settings and returns to the normal charging display. Recheck each setting before leaving the system unattended.

CHARGING STAGES

The controller automatically changes charging stage according to battery voltage, charging current and the selected battery profile.

Crystal, Gel, AGM, WET, Calcium

LCO, LFP, LTO

 Stage What the controller does
Soft start When an over-discharged battery is detected, charging is gently increased until the battery reaches approximately 10V.
Bulk The controller supplies the maximum available charging current until the absorption voltage is reached.
Absorption The charging voltage is held constant while current reduces. The maximum absorption time is 4 hours for lead-acid profiles and 0.5 hour for lithium profiles.
Equalisation For WET and Calcium profiles only. It may start when the battery is below 10V or at the 28-day interval. The stage is limited to 2 hours.
Float / restart Lead-acid batteries are maintained at float voltage. Lithium charging stops after absorption and restarts when the battery falls to the profile restart voltage.

Lithium BMS Activation

If a lithium battery has entered BMS over-discharge protection, it can be woken up by using the manual BMS wake-up function.

To start the activation manually, hold BATT / + for 3 seconds. The LCD bar rotates while activation is in progress. Note that the MPPT must be in LFP mode for this function to activate.

Note: If the battery BMS does not activate, follow the battery manufacturer's recovery procedure before continuing.

LED INDICATIONS

Normal Charging Indications

 LED indications

LED Colour

Green Blue White White White White
Soft-Start ON FLASH FLASH OFF OFF OFF
Bulk Charge ON ON ON FLASH OFF OFF
Absorption / Equalization ON ON ON ON ON FLASH
Float Charge ON OFF ON ON ON ON

Fault Codes

 Fault Code LCD Display Condition Action
/ / Solar input is weak - below 15V Check sunlight, panel coverage and solar wiring.
P-01 Solar polarity is reversed Isolate the array and correct the PV polarity.
P-02 Solar input voltage is above 95V Isolate the array and reduce the PV string voltage.
b-01 Solar is connected but the battery is disconnected Isolate the solar array, reconnect the battery and check its fuse.
b-02 Battery polarity is reversed Isolate all sources and correct the battery polarity.
b-03 Battery over-voltage - above 17V / 34V Check the battery voltage and system-voltage setting.
b-04 Battery temperature is above 65°C Stop charging, allow the battery to cool and inspect the temperature sensor.
OTP Controller over-temperature protection Allow the controller to cool and improve ventilation.

MAINTENANCE

We recommend performing the below maintenance checks at a minimum every 3 months:

  • Isolate the solar array and battery before cleaning or inspecting the controller.
  • Wipe the case with a damp cloth and mild cleaning agent. Do not allow water to enter the controller.
  • Check terminals regularly for looseness, corrosion, heat damage or damaged insulation.
  • Have damaged cables or connectors replaced by a qualified person.

SPECIFICATIONS

 Electrical Parameters HKPSOLR40A HKPSOLR60A
Maximum PV open-circuit voltage at −20°C 100V DC
Maximum normal PV input voltage at 25°C 94V DC
Maximum PV input current 40A 60A
Maximum PV short-circuit current 45A 65A
Maximum rated charging current 40A 60A
Maximum conversion efficiency 98%
Minimum tracking efficiency 99.5%
Maximum recommended PV input power 600 W (12 V) / 1200 W (24 V) 900 W (12 V) / 1800 W (24 V)
Battery self-consumption when PV is disconnected 10 ± 0.5mA
Maximum output open-circuit voltage when battery is disconnected 0.5V DC
Maximum MPP voltage range 15–72 ± 0.5V DC
Charging characteristics
Minimum battery voltage to start charging 5V DC / 10V DC
Soft-start charging voltage 5–10 ± 0.2V DC / 10–20 ± 0.2V DC
Soft-start charging current 20A 30A
Maximum bulk charging current 40A 60A
Absorption charging voltage at 25°C
LCO battery 12.6 ± 0.2V DC / 25.2 ± 0.2V DC
LTO battery 14.0 ± 0.2V DC / 28.0 ± 0.2V DC
LFP battery 14.2 ± 0.2V DC / 28.4 ± 0.2V DC
Gel battery 14.1 ± 0.2V DC / 28.2 ± 0.2V DC
AGM battery (default setting) 14.4 ± 0.2V DC / 28.8 ± 0.2V DC
WET battery 14.7 ± 0.2V DC / 29.4 ± 0.2V DC
Lead Crystal battery 14.7 ± 0.2V DC / 29.4 ± 0.2V DC
Calcium battery 14.9 ± 0.2V DC / 29.8 ± 0.2V DC
Custom 13.2–15.5 ± 0.2V DC / 26.4-31 ± 0.2V DC
Absorption transition to equalisation or float/stop
Charging current drops to 2.5 ± 0.1A
or Absorption charging timed out for Crystal, Gel, AGM, WET, Calcium 4 hours
or Absorption charging timed out for LCO, LFP, LTO 0.5 hours

Equalisation charging activation 

WET or Calcium only
Battery voltage falls below 10 ± 0.2V DC / 20 ± 0.2V DC
Automatic equalisation charging interval 28 days
Equalisation charging timeout 2 hours
Equalisation charging voltage at 25°C 15.5 ± 0.2V DC / 31 ± 0.2V DC
Equalisation charging timeout 2 hours

Float voltage at 25°C

Crystal, Gel, WET, AGM, Calcium

13.6 ± 0.2V DC / 27.2 ± 0.2V DC

Restart voltage

Crystal, Gel, WET, AGM, Calcium 12.7 ± 0.2V DC / 25.4 ± 0.2V DC
LCO 12.0 ± 0.2V DC / 24 ± 0.2V DC
LTO 13.0 ± 0.2V DC / 26 ± 0.2V DC
LFP 13.3 ± 0.2V DC / 26.6 ± 0.2V DC
Custom 12.5–13.5 ± 0.2V DC / 25–27 ± 0.2V DC
Voltage control accuracy ±1%
Battery temperature compensation coefficient −24mV/°C
Electrical parts
Input/output terminals Rated 40A connector Rated 60A connector
Physical parameters
Controller material Plastic, PC
Mounting Surface mounting
IP rating IP43
Net weight 1.2kg 1.9kg
Environmental characteristics
Operating temperature −25 to 50°C / −13 to 122°F
Storage temperature −40 to 85°C / −40 to 185°F
Operating humidity range 0–85% RH

Note: 12V output value / 24V output value